GRID & SILICON LESSONS · LESSON 8
Carry the Heat Outside
GRID & SILICON - LEARN - ACTIVITY Carry the Heat Outside
Cooling Towers and Dry Coolers: Where Data Center Heat Goes
Initials ________ Date ____________________
Almost all the electricity a chip uses turns into heat. That heat has to travel all the way outside, or the chip gets too hot and can slow down or break. Here you feel how evaporation carries heat away, walk the heat along its path, and choose a cooler for two towns.
Left: a cooling tower lets some water evaporate and leave as vapor. Right: a dry cooler uses fans and air, and no evaporating
water.
Time: 20-25 minutes Works for: 1 student on their own, 1 student with a partner, or 1 student with a teacher or parent You need: 2 paper towels, a small cup of plain tap water, a sheet of stiff paper to fan with, 6 small slips of paper, and a pencil
On your own: Do every step yourself; read each question aloud quietly, then write or draw your answer. With a partner: Take turns - one does a step, the other reads it aloud and watches; swap jobs at each part. With a teacher or parent: They read with you, fan the towel in Part A, and ask the Discuss questions at the end. You make every choice and give every answer.
Part A: Feel evaporation carry heat away
1. Predict first. Circle one: A wet paper towel on my arm will feel cooler / the same / warmer than a dry one
when I fan it.
2. Lay the dry paper towel on the back of your hand or arm. Fan it with the stiff paper for a slow count of 10.
Notice how it feels.
3. Dip the second paper towel in the cup of water and squeeze out the drips. Lay it on the same spot. Fan it
for a slow count of 10.
4. Swap and repeat once, so you are sure. If you have a partner or teacher, they fan while you feel, then you
swap.
Test How did it feel? Circle or write.
Dry towel, fanned cool / a little cool / not cool
Wet towel, fanned cool / a little cool / not cool
Finish the sentence: The wet towel felt cooler because the water ____________________ and took heat from my skin with it.
Safety: Use only plain tap water at room temperature. Never use hot water, and keep water away from computers, outlets, and power strips.
Cooling Towers and Dry Coolers: Where Data Center Heat Goes - Grid & Silicon Learn Page 1 of 3
Part B: Walk the heat from the chip to the outside air
Heat always moves from a warmer place to a cooler place. Follow it, one stop at a time.
1. Write one label on each slip of paper: Chip, Cold plate, Coolant loop, Cooling tower, Dry cooler,
Outside air. Lay the first three slips in a row on the table. Put both cooler slips below them, then the Outside air slip after both.
2. Put your pencil on the Chip slip. That is your heat. Say where the heat is, then slide the pencil to the next
stop. The cold plate touches the chip, so heat moves from the chip into the cold plate, and then into the coolant - the liquid that carries heat away from hot parts.
3. Slide the pencil around the Coolant loop twice. The loop is closed, so the same coolant goes around again
and again. It is not used up.
4. Now choose a fork and finish the trip. Do both forks, one at a time.
Fork 1 - Cooling tower. Mime spraying water with one hand. Wave the other hand up and away: some of the water evaporates, becomes vapor, and leaves in the air. That water does not come back. Some leftover water is also drained away as blowdown, because it has too many minerals.
Fork 2 - Dry cooler. Fan the air fast with both hands like the big fans. Air blows past tubes with thin metal fins and carries the heat away. No water evaporates - but on a very hot day the fans have to work harder, so the cooler can use more electricity.
Tell it back. Point to each slip and say the whole trip out loud in one breath, from chip to outside air. If you are working alone, whisper it. If you have a partner or teacher, they listen and point to any stop you miss.
Part C: Pick a cooler for two towns
There is no perfect cooler. Picking one is a tradeoff: you give up some of one thing to get more of another.
Town My pick (circle one) Why? Finish: I pick it because...
Desert town. Very hot summers. Water is scarce and must be saved.
Cooling tower Dry cooler
River town. Plenty of water all year. Electricity is expensive.
Cooling tower Dry cooler
Name the tradeoff for the desert town:
Cooling Towers and Dry Coolers: Where Data Center Heat Goes - Grid & Silicon Learn Page 2 of 3
Discuss, check, and finish
Discuss together
If you are on your own, answer out loud or in writing. With a partner or teacher, take turns answering first.
Where did the water go in the cooling tower fork? Why can the data center not just use that same water again?
Why does the dry cooler save water, and what does it give up on a very hot day?
The coolant in the loop is never used up, but cooling tower water is. What makes them different?
Exit ticket
Cut or copy these three questions. One or two sentences each is enough. You can answer all of them from the explainer alone.
1. Trace the heat: name every stop from the chip to the outside air, in order.
2. How does a cooling tower carry heat away, and what happens to the water that does the job?
3. A town has very little water. Which cooler would you choose, and what is the tradeoff?
Support and stretch
Support: Offer extra time, a quiet space, and breaks. Accept spoken or drawn answers before writing. Leave the Part B station row on the page in view while answering, and let the student hold the wet and dry towels again during Part C.
Stretch: Add blowdown to your Part B trip: explain where it fits and why it happens. Or draw both forks as one diagram, labeling vapor, fins, and fans, and write one sentence under each fork naming what it uses more of - water or electricity.
For the teacher, parent, or partner - quick check: Part A: evaporates (accept: turns into vapor / changes into a gas). Desert town: dry cooler - it saves water; the tradeoff is more electricity on hot days. River town: cooling tower - it saves electricity; the tradeoff is more water used, lost as vapor and blowdown. Exit ticket 1 order: chip, cold plate, coolant loop, cooling tower or dry cooler, outside air.
Cooling Towers and Dry Coolers: Where Data Center Heat Goes - Grid & Silicon Learn Page 3 of 3